The rated current of the cryostat should not be less than 10A


Shanghai Haozhuang Instrument Co., Ltd. has developed the LNB brand low-temperature constant temperature series, which is very good in quality and low in price. Welcome your purchase!
Internal structure and principle of use:
1. Low temperature thermostat parts: compressor, condenser, evaporator, fan (inside and outside) circulating water pump, stainless steel liner, heating tube, intelligent temperature control meter.
2. The internal operating principle of the low-temperature tank: after the compressor is operated, it will be vaporized by suction-compression-exhaust-condensation-throttling-and then low-temperature evaporation to absorb heat. The water temperature will be reduced to the temperature set by the temperature control table, such as temperature control The table setting temperature is higher than normal temperature. The contactor in the temperature control meter works automatically, giving the heating tube a current signal, the heating tube starts to work, when working in the low temperature constant temperature bath. The inlet and outlet of the whole machine can be used for internal circulation or external circulation of the internal water source, and the internal water source can also be led out. Do the second constant temperature field outside the cryostat.
How to use the cryostat The instrument uses 220V AC power, please make sure that the rated current of the power socket is not less than 10A before use, and it has a safety grounding device (please connect the grounding device to the working room when using it). When adding water, please note that it is not less than 8cm away from the upper cover. Soft water must be used, preferably distilled water. Do not use well water, river water, spring water or other hard water to prevent the heating tube from bursting and affecting the constant temperature sensitivity. Please use it correctly according to the instructions of the temperature control instrument, set the required temperature value> first turn on the power, set the required temperature value on the instrument according to the instruction, when the temperature reaches the set temperature, you can turn on the cycle switch, so All programs enter the normal working state.
Precautions for use 1. Add a liquid medium into the front tank of the low-temperature constant temperature bath, the liquid level of the medium should be about 30mm lower than the worktable, otherwise the heater will be damaged when energized;
2. The selection of the liquid medium in the low-temperature constant temperature bath should meet the following principles:
When the working temperature is 5 ~ 85 ℃, the liquid medium generally uses water;
When the working temperature is 85 ~ 95 ℃, the liquid medium can choose 15% glycerin aqueous solution;
When the working temperature is higher than 95 ° C, the liquid medium generally uses oil, and the open cup flash point of the selected oil should be higher than the working temperature by more than 50 ° C;
3. Power supply: 220V50Hz, the power supply should be greater than the total power of the instrument, the power supply must have a good "ground" device;
4. The instrument should be placed in a dry and ventilated place with no obstacles within 300mm around the instrument;
5. When the working temperature of the constant temperature bath is high, you should be careful not to open the upper cover and do not enter your hand with the hand to prevent burns;
6. After use, all switches are turned off to cut off the power supply;
The instrument should do regular cleaning work to keep the work surface and operation panel clean;

Always pay attention to observe the liquid level in the tank. When the liquid level is too low, the liquid medium should be added in time; considering the safety factors, we stipulate that the constant temperature tank above 100 ℃ is made into an internal circulation. If the external circulation is changed according to the customer's requirements, the customer should pay special attention to the firmness of the connection of the outlet pipe to prevent it from falling off to avoid burns.

Shanghai Haozhuang Instrument Co., Ltd. is a laboratory instrument manufacturer integrating R & D, production, sales and service. The company brings together many technical talents and advanced production equipment in electronics, refrigeration, design, manufacturing, etc., and focuses on high-tech fields such as experimental instruments and biomedical engineering. The company's research and development team has rich product experience and industry experience for our technology. The service provides a reliable guarantee. The company's main research and development and production: low temperature constant shaker temperature tank, snowflake ice machine, ultrasonic cleaning machine, ultrasonic cell crusher, sterile homogenizer, low temperature coolant circulation pump, low temperature thermostat circulator, constant temperature water tank / oil tank, high temperature circulation Device, snowflake ice machine, freeze dryer, chromatography experiment freezer, double glass reactor, water bath and other biochemical experiment equipment. It is a high-tech enterprise specialized in providing biochemical instruments, analytical instruments, glass instruments, and laboratory products.

STRUCTURE

Screen printer has a more simple structure:
1) Working table: Install fixture and substrates. There are five kinds of working table: Flat, round, oval, T model, vacuum. T model working table and vacuum working table keep stillness when printing; other kinds of working table can move up and down when printing, In order to improve production efficiency , conveyor working table installed on flat screen printer, this kind of screen printer is suitable printing small dimension objects.
2) Screen frame combination: Install screen plate and store ink.When printing flat products, frame keep stillness; when printing cylinder, screen frame move from left to right.
3) Squeegee nip combination: Install rubber squeegee and supply ink for coating on the surface of silk. Rubber blade move up-and-down, meantime ink floor move with opposition direction. When printing flat products, squeegee nip combination move left to right, when printing cylinder products, they keep stillness. Squeegee rubber finish printing and ink floor finish coating.

4)Operation controlling system : Most of screen printer controlled by micro-computer built in to make machine stability and easy to operate. When testing, only press simple action key and when starting automatic key to begin printing will be helpful to operate screen printer.

 MAINLY FACTOR

1)         Screen plate: 
         Making screen plate through three kinds of way: emulsion, direct film, indirect film. Different substrates need different technology parameter such as: silk tension, count, thickness of emulsion. Water base and solvent base emulsion coated according to different products.
2)       Screen ink:
       Choosing solvent screen ink, UV ink and function plasma according to printing request. Ink must be test before printing.
3)       Rubber squeegee:
             Ink pressed to deposit onto the products by rubber squeegee. Rectangle squeegee is for flat substrate and triangle squeegee is for cylinder substrate. Harder squeegee get more precision printing result than softer squeegee.
4)       Fixture:
             It is important to make fixture according to products. Regular products need the fixture made by lathe or CNC. Complex products need the fixture made by polyester resin. Round products need same diameter transmission gear with product diameter.
SORTS
  Manual controllingcompression air controlling screen printerPlastics bottel multi-color cylinder screen printerRound screen printer. oval screen printer. T model screen printer, vacuum table screen printer single-piece screen printer, electron controlling, to be sorted according to action supply. Most of screen printer in china market is controlled by compression air.
2. One color, two colors, screen printer to be sorted according to max printing color numbers. One color screen printer print one color one time; Two Colors Pad Printer print two colors in one product one time. One color screen printer is simpler, but multi-color screen printer has more complex structure and volume. widely use in printing cosmetic and other industry package.
3. to be sorted according to different working table installed. Round working table screen printer print round products; oval working table one print oval bottle; T model screen printer print rigid flat products and vacuum table screen printer print paper and soft film products.
4. Different feed transmission way sort screen printer as and web-roller screen printer. Most of screen printer is single-piece screen printer.   




Screen Printing Machine

Screen Printing Machine,Automatic Screen Printing Machine,Automatic Screen Printer,Bucket Pneumatic Screen Printing Machine,Fabric Screen Printing Machine

KC Printing Machine (Group) Limited , http://www.kcautopm.com

Posted on